An Al$^+$ clock with $1.6\times10^{-18}$ systematic uncertainty and its frequency ratios
📄 arXiv:2606.23151 · 📥 PDF · 2026-06-22 · physics.atom-ph
Authors: Fabian Dawel [arXiv · scholar] , Johannes Kramer [arXiv · scholar] , Derwell Drapier [arXiv · scholar] , Lennart Pelzer [arXiv · scholar] , Kai Dietze [arXiv · scholar] , Mirza A. Ali [arXiv · scholar] , Marek Hild [arXiv · scholar] , Vincent Barbé [arXiv · scholar] , Steven A. King [arXiv · scholar] , Joshua Klose [arXiv · scholar] , Kilian Stahl [arXiv · scholar] , Johannes Rahm [arXiv · scholar] , Navraj Poudel [arXiv · scholar] , Sören Dörscher [arXiv · scholar] , Stefan Weyers [arXiv · scholar] , Erik Benkler [arXiv · scholar] , Christian Lisdat [arXiv · scholar] , Piet O. Schmidt [arXiv · scholar]
🕰 Orloj analysis
Tento článek představuje podrobné vyhodnocení systematických posunů frekvence optických hodin na bázi iontu $^{27}\mathrm{Al}^+$, dosahující systematické nejistoty $1.6\times10^{-18}$. Byly změřeny absolutní frekvence hodin a jejich frekvenční poměr s hodinami $^{87}\mathrm{Sr}$, přičemž výsledky se liší od předchozích měření BACON spolupráce, což zdůrazňuje potřebu nezávislých ověření pro redefinici sekundy.
💡 Jde o významný pokrok v přesné metrologii, který posouvá hranice měření času a je klíčový pro budoucí redefinici sekundy, byť se jedná o inkrementální zlepšení v rámci zavedené metodiky.
✓ falsifiable, modest_claims, limit_reductions
📄 Abstract
Advances in optical clocks motivate a redefinition of the second, requiring rigorous evaluations of systematic uncertainties and robust consistency among the clocks. Here, we report the full evaluation of the systematic frequency shifts of an $^{27}\mathrm{Al}^+$ single-ion clock, and the measurement of its absolute frequency and frequency ratio with a $^{87}$Sr optical lattice clock at PTB. The evaluated total systematic fractional frequency uncertainty is $1.6\times10^{-18}$, mainly limited by the accuracy of the relevant atomic coefficients and by background gas collisions. The absolute frequency of the clock has been measured to be $ν_{\mathrm{Al}^+}=1 121 015 393 207 859.19(24)\,$Hz, obtained by comparison with two primary caesium fountain clocks at PTB. The frequency ratio between the Al and Sr optical clocks has been determined to be $ν_{\mathrm{Al}^+}/ν_{^{87}\mathrm{Sr}}=2.611 701 431 781 462 668(36)$, limited by the accuracy of the Sr clock. This ratio differs by $8.6σ$ and $1.2σ$ from the 2021 and 2025 frequency ratio published by the BACON collaboration, respectively. These results represent an important contribution toward a future redefinition of the second using optical clocks, and underscore the importance of independent measurements of clock-candidate frequency ratios across different institutions.