Benchmarking Dark Matter Search using a Parity-Check Protocol with Machine-Learning Optimized Pulses
📄 arXiv:2606.25795 · 📥 PDF · 2026-06-24 · gr-qc
Authors: Yu-Han Chang [arXiv · scholar] , Ilya Moskalenko [arXiv · scholar] , Marko Kuzmanović [arXiv · scholar] , Ognjen Stanisavljević [arXiv · scholar] , Isak Björkman [arXiv · scholar] , David Díez-Ibáñez [arXiv · scholar] , Yikun Gu [arXiv · scholar] , Akash V. Dixit [arXiv · scholar] , Igor G. Irastorza [arXiv · scholar] , Gheorghe Sorin Paraoanu [arXiv · scholar]
🕰 Orloj analysis
Tento článek popisuje vylepšený protokol pro detekci kandidátů na temnou hmotu (axion, temný foton) pomocí supravodivého transmon qubitu a dvojitého rezonátoru s pulzy optimalizovanými strojovým učením. Autoři experimentálně validovali metodu a stanovili exkluzivní limity pro model temného fotonu s citlivostí ε_95% ~ 1x10^-14.
💡 Práce představuje významný metodologický pokrok v oblasti kvantových senzorů pro detekci temné hmoty, kombinující pokročilé kvantové řízení s optimalizací strojovým učením pro zvýšení citlivosti a rychlosti.
Categories:
PRT-6
EXP-4
MET-5
GRV-5
✓ falsifiable, modest_claims
⚠ Category gr-qc seems unusual for a dark matter detection paper using quantum sensors, typically hep-ex or quant-ph., No explicit mention of code availability for ML optimization or HMM analysis., The setup operates despite significantly reduced qubit coherence times and storage-cavity lifetimes, requiring compensation.
📄 Abstract
We report on an improved microwave detection protocol for dark matter candidates such as the axion and the dark photon. We employ a superconducting transmon qubit dispersively coupled to a double-cavity system, enabling quantum non-demolition measurements of the photon occupation in a relatively short-lived storage cavity. To reduce the experimental cycle time and enhance sensitivity for axion and dark-photon searches, we operate this detector in a regime of increased qubit-cavity coupling, resulting in Stark shifts of 4.6 MHz. In this regime, conventional control pulses suffer from strong frequency-detuning sensitivity and photon-number-dependent errors. We address this limitation by implementing frequency-detuning-robust $π/2$ pulses (obtained by machine-learning optimization) that preserve high-fidelity qubit control over a bandwidth of approximately 20 MHz. We experimentally validate this protocol and demonstrate single-photon detection performance comparable to previous implementations, despite significantly reduced qubit coherence times and storage-cavity lifetimes. Using parity-based measurement sequences combined with a Hidden Markov Model (HMM) analysis, we achieve background rates on the order of $\mathcal{O}(20)$ Hz. In the absence of a magnetic field, we derive exclusion limits on the dark photon model for dark matter, reaching a sensitivity to the kinetic mixing angle of $ε_{95\%} \sim 1\times10^{-14}$ at 5.051 GHz. These results establish machine-learning robust control as a key enabler for faster, more scalable microwave quantum sensors for dark-matter searches.