GroundBIRD: First On-Sky Responsivity Calibration at the Teide Observatory
📄 arXiv:2607.10845 · 📥 PDF · 2026-07-12 · astro-ph.CO
Authors: Alessandro Fasano [arXiv · scholar] , Yonggil Jo [arXiv · scholar] , Ricardo Tanausú Génova-Santos [arXiv · scholar] , Makoto Hattori [arXiv · scholar] , Shunsuke Honda [arXiv · scholar] , Kenichi Karatsu [arXiv · scholar] , Chiko Otani [arXiv · scholar] , Michael Peel [arXiv · scholar] , José Alberto Rubiño-Martín [arXiv · scholar] , Yoshinori Sueno [arXiv · scholar] , Junya Suzuki [arXiv · scholar] , Osamu Tajima [arXiv · scholar] , Tomonaga Tanaka [arXiv · scholar] , Miku Tsujii [arXiv · scholar] , Eunil Won [arXiv · scholar]
🕰 Orloj analysis
Tento článek představuje první kalibraci citlivosti detektorů experimentu GroundBIRD na obloze, prováděnou pomocí pozorování Jupiteru. Metodologie kalibrace je ověřena a je empiricky popsána závislost citlivosti detektorů na množství vodní páry v atmosféře.
💡 Jde o klíčový instrumentální příspěvek pro experiment GroundBIRD, který poskytuje nezbytnou kalibraci a empirické charakteristiky detektorů, což je zásadní pro budoucí vědecké výsledky.
Categories:
EXP-7
EXP-1
MET-2
MET-1
✓ falsifiable, modest_claims
⚠ code_not_available, calibration_limited_to_subset_of_detectors
📄 Abstract
GroundBIRD is a cosmic microwave background (CMB) experiment located at the Teide Observatory (altitude $\sim2400$ m, Spain) designed to measure large-angular-scale intensity and polarization anisotropies ($\ell \gtrsim 6$ to $\ell \sim 300$) to constrain the reionization optical depth, $τ$. The instrument employs a rapidly rotating telescope with a fixed elevation of $70$ deg and is equipped with 161 lenslet-coupled kinetic inductance detectors (KIDs): 138 at 145 GHz for CMB observations and 23 at 220 GHz for thermal dust characterization, all operated at $\sim280$ mK. This scan strategy provides daily coverage of $\sim$40% of the Northern Hemisphere sky. We present the first on-sky responsivity calibration model for GroundBIRD, derived from repeated observations of Jupiter using the twelve most stable KIDs from GroundBIRD array 6 (GB06). The analysis establishes and validates a calibration methodology for this detector subset while providing the first empirical characterization of detector responsivity as a function of precipitable water vapor (PWV). We find that the responsivity decreases by approximately 30% across the sampled PWV range and is well described by a linear PWV-dependent model. Comparison with Moon observations reveals distinct detector operating regimes associated with different optical loading conditions. The Jupiter-based calibration achieves better than 20% precision under typical observing conditions and better than 20% relative stability over a one-month timescale. These results establish the basis for extending the calibration methodology to the full GroundBIRD focal plane.