← back

Axion dark matter search with a photonic bandgap cavity haloscope and dielectric tuning rod over 10.25-10.45 GHz

📄 arXiv:2608.07718 · 📥 PDF · 2026-08-07 · astro-ph.CO

Authors: Morgan Lynn [arXiv · scholar] , Ankur Agrawal [arXiv · scholar] , Arjun Ghosh [arXiv · scholar] , Sara Sussman [arXiv · scholar] , Steven G. Johnson [arXiv · scholar] , David I. Schuster [arXiv · scholar] , Aaron S. Chou [arXiv · scholar]

📄 Abstract

We report the development of a new widely tunable cavity and demonstrate its use in a search for dark matter axions. We achieve unloaded quality factors above $10^{5}$, roughly $25\times$ larger than a bare copper cavity at the same frequency, using concentric sapphire shells to reduce Ohmic losses on the cavity barrel. A rotating sapphire rod tunes our cavity mode over the $10.1-11.7$ GHz range, approximately $16\%$ of its resonant frequency. Using an amplified receiver chain, we demonstrate sensitivity to new axion parameter space by tuning the cavity over the $200$ MHz range between $10.25-10.45$ GHz (42.4 - 43.2, $μ$eV) to constrain the axion-to-photon coupling to $|g_{aγγ}|$ $\leq$ 1 $\times$ $10^{-12}$ ${GeV}^{-1}$. This cavity can scan its tuning range about $9$ times faster compared to a bare copper cavity when paired with a photon counting device, laying the groundwork for a definitive search for the QCD axion over $10.1-11.7$ GHz.

📄 arXiv abstract page 📥 PDF