Aliased noise characterization and mitigation in BICEP Array 150, 220 and 270 GHz time-division multiplexed detectors
๐ arXiv:2608.25011 ยท ๐ฅ PDF ยท 2026-08-25 ยท astro-ph.CO
Authors: S. Fatigoni [arXiv ยท scholar] , P. A. R. Ade [arXiv ยท scholar] , Z. Ahmed [arXiv ยท scholar] , M. Amiri [arXiv ยท scholar] , D. Barkats [arXiv ยท scholar] , R. Basu Thakur [arXiv ยท scholar] , C. A. Bischoff [arXiv ยท scholar] , D. Beck [arXiv ยท scholar] , J. J. Bock [arXiv ยท scholar] , V. Buza [arXiv ยท scholar] , B. Cantrall [arXiv ยท scholar] , J. R. Cheshire [arXiv ยท scholar] , J. Connors [arXiv ยท scholar] , J. Cornelison [arXiv ยท scholar] , M. Crumrine [arXiv ยท scholar] , A. J. Cukierman [arXiv ยท scholar] , E. Denison [arXiv ยท scholar] , L. Duband [arXiv ยท scholar] , M. A. Echter [arXiv ยท scholar] , M. Eiben [arXiv ยท scholar] , B. D. Elwood [arXiv ยท scholar] , J. P. Filippini [arXiv ยท scholar] , A. Fortes [arXiv ยท scholar] , M. Gao [arXiv ยท scholar] , C. Giannakopoulos [arXiv ยท scholar] , N. Goeckner-Wald [arXiv ยท scholar] , D. C. Goldfinger [arXiv ยท scholar] , S. Gratton [arXiv ยท scholar] , J. A. Grayson [arXiv ยท scholar] , A. Greathouse [arXiv ยท scholar] , P. K. Grimes [arXiv ยท scholar] , M. Halpern [arXiv ยท scholar] , S. Henderson [arXiv ยท scholar] , T. D. Hoang [arXiv ยท scholar] , J. Hubmayr [arXiv ยท scholar] , H. Hui [arXiv ยท scholar] , K. D. Irwin [arXiv ยท scholar] , M. Izquierdo Poza [arXiv ยท scholar] , J. H. Kang [arXiv ยท scholar] , K. S. Karkare [arXiv ยท scholar] , S. Kefeli [arXiv ยท scholar] , J. M. Kovac [arXiv ยท scholar] , C. Kuo [arXiv ยท scholar] , K. Lasko [arXiv ยท scholar] , K. Lau [arXiv ยท scholar] , M. Lautzenhiser [arXiv ยท scholar] , T. Liu [arXiv ยท scholar] , S. C. Mackey [arXiv ยท scholar] , N. Maher [arXiv ยท scholar] , K. G. Megerian [arXiv ยท scholar] , L. Minutolo [arXiv ยท scholar] , L. Moncelsi [arXiv ยท scholar] , Y. Nakato [arXiv ยท scholar] , H. T. Nguyen [arXiv ยท scholar] , R. O'Brient [arXiv ยท scholar] , S. N. Paine [arXiv ยท scholar] , A. Patel [arXiv ยท scholar] , M. A. Petroff [arXiv ยท scholar] , A. R. Polish [arXiv ยท scholar] , T. Prouve [arXiv ยท scholar] , C. Pryke [arXiv ยท scholar] , C. D. Reintsema [arXiv ยท scholar] , T. Romand [arXiv ยท scholar] , M. Salatino [arXiv ยท scholar] , A. Schillaci [arXiv ยท scholar] , B. Schmitt [arXiv ยท scholar] , B. Singari [arXiv ยท scholar] , A. Soliman [arXiv ยท scholar] , T. St. Germaine [arXiv ยท scholar] , A. Steiger [arXiv ยท scholar] , B. Steinbach [arXiv ยท scholar] , R. Sudiwala [arXiv ยท scholar] , K. L. Thompson [arXiv ยท scholar] , C. Tucker [arXiv ยท scholar] , A. D. Turner [arXiv ยท scholar] , C. Vergรจs [arXiv ยท scholar] , A. G. Vieregg [arXiv ยท scholar] , A. Wandui [arXiv ยท scholar] , A. C. Weber [arXiv ยท scholar] , J. Willmert [arXiv ยท scholar] , W. L. K. Wu [arXiv ยท scholar] , H. Yang [arXiv ยท scholar] , C. Yu [arXiv ยท scholar] , L. Zeng [arXiv ยท scholar] , C. Zhang [arXiv ยท scholar] , S. Zhang [arXiv ยท scholar]
๐ Abstract
Early observations with the BICEP Array 150 GHz (BA2-150) and 220/270 GHz (BA3-220/270) receivers revealed detector noise equivalent temperatures (NETs) higher than expected, together with substantial detector-to-detector and module-to-module scatter. Noise measurements acquired with multiplexing off and high frequency sampling demonstrate that this excess originates from elevated high-frequency detector noise that aliases into the science band during time-division multiplexing. We show that the excess high-frequency noise is correlated with anomalously large logarithmic TES transition slopes, ฮฑ, resulting in elevated electrothermal loop gain and operation near the detector stability boundary. Measurements of ฮฑ indicate values substantially larger than expected, consistent with the sharper superconducting transitions introduced by the inverted TES fabrication process adopted for BA2-150 and BA3-220/270 detectors. Operational mitigation strategies were investigated through both increased multiplexing rates and elevated focal-plane operating temperatures. Faster multiplexing reduces aliasing by shifting the multiplexing Nyquist frequency beyond the excess noise roll-off, while elevated bath temperatures reduce TES electrical power and loop gain, improving detector stability and reducing NET by approximately 10%. These results demonstrate the importance of balancing TES responsivity, electrothermal stability, and multiplexed readout performance in next-generation CMB polarimeters.